{"id":3524,"date":"2021-11-12T20:53:10","date_gmt":"2021-11-12T19:53:10","guid":{"rendered":"http:\/\/www.gtronic.it\/test\/?page_id=3524"},"modified":"2023-03-08T10:01:22","modified_gmt":"2023-03-08T09:01:22","slug":"allarmi-impostazione-per-le-cpu-1200-e-1500","status":"publish","type":"page","link":"https:\/\/www.gtronic.it\/test\/index.php\/allarmi-impostazione-per-le-cpu-1200-e-1500\/","title":{"rendered":"Allarmi &#8211; Impostazione per le CPU 1200 e 1500"},"content":{"rendered":"<p><strong>How to setup allarms.<\/strong><\/p>\n<p>The alarms generation is handle easily on the HMI interface.<\/p>\n<p>Download example TIAV15, CPU 1214C DC\/DC\/DC ag40 -&gt;\u00a0\u00a0<a href=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/Gestione-Allarmi.zip\">Gestione Allarmi<\/a><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2504\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/1-1.png\" alt=\"1\" width=\"1027\" height=\"625\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/1-1.png 1027w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/1-1-300x183.png 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/1-1-768x467.png 768w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/1-1-1024x623.png 1024w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/1-1-493x300.png 493w\" sizes=\"(max-width: 1027px) 100vw, 1027px\" \/><\/p>\n<p>Gli allarmi possono essere generati su evento hardware o software, come anche da una richiesta di bordo macchina ovvero da sensori o stati degli attuatori. Quando un allarme si presenta viene mostrato nella sua sequenza temporale nel visualizzatore per righe del HMI abbinato al Time stamp.\u00a0 Viene attivata anche una registrazione storica.<\/p>\n<p>Predisporre il sistema creando una pagina HMI che contenga un pulsante per la generazione di un allarme e uno per il reset dello stesso.\u00a0 Dal men\u00f9 HMI allarms, sul lato destro dello schermo, trascinare il control panel degli allarmi.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2505\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/2-1.png\" alt=\"2\" width=\"901\" height=\"431\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/2-1.png 901w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/2-1-300x144.png 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/2-1-768x367.png 768w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/2-1-500x239.png 500w\" sizes=\"(max-width: 901px) 100vw, 901px\" \/><\/p>\n<p>Definiamo le variabili nella default Tags table del pannello operatore HMI e non nel PLC, come mostrato nell&#8217;immagine, ad esempio la variabile HMI temperatura dei silos contiene tre possibilit\u00e0 abbinate a tre trigger diversi.<\/p>\n<p>I trigger sono i bit impostati dall&#8217;evento che scatena l&#8217;allarme.\u00a0 Questi sono i bit, presi in maniera ordinata, ad esempio 0,1,2,.ecc all&#8217;interno della variabile INT definita in HMI. E&#8217; obbligatorio definirla INT, non \u00e8 possibile scatenare l&#8217;allarme su variabili Bool come sarebbe pi\u00f9 logico.<\/p>\n<p>Ora definiamo i Discrete allarm, sinonimo di &#8220;lanciati da un evento booleano.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2506\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/3-1.png\" alt=\"3\" width=\"1105\" height=\"498\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/3-1.png 1105w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/3-1-300x135.png 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/3-1-768x346.png 768w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/3-1-1024x461.png 1024w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/3-1-500x225.png 500w\" sizes=\"(max-width: 1105px) 100vw, 1105px\" \/><\/p>\n<p>Definiamo gli allarmi ne DB globale del PLC.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2507\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/4-1.png\" alt=\"4\" width=\"921\" height=\"278\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/4-1.png 921w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/4-1-300x91.png 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/4-1-768x232.png 768w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/4-1-500x151.png 500w\" sizes=\"(max-width: 921px) 100vw, 921px\" \/><\/p>\n<p>Download screenshot of\u00a0program draft .docx -&gt;\u00a0<a href=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/esempio-allarmi.docx\">esempio allarmi<\/a><\/p>\n<hr \/>\n<p><strong>Allarmi da analogici temperatura<\/strong><\/p>\n<p>Questo esempio genera allarmi di massima e minima temperatura, inoltre segnala se si \u00e8 rotta la sonda di temperatura. Un esempio perfetto sia per la didattica che per la professione.\u00a0 Questo esempio \u00e8 contenuto nel libro di testo Let&#8217;s Program a PLC edizione 2022.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3578\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2021\/11\/allarmi-HMI.png\" alt=\"allarmi HMI\" width=\"663\" height=\"486\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2021\/11\/allarmi-HMI.png 663w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2021\/11\/allarmi-HMI-300x220.png 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2021\/11\/allarmi-HMI-409x300.png 409w\" sizes=\"(max-width: 663px) 100vw, 663px\" \/><\/p>\n<p>download esempio completo\u00a0<a href=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2021\/11\/Allarmi-HMI.zip\">Allarmi HMI<\/a><\/p>\n<p>Nel video che segue c&#8217;\u00e8 un esempio svolto dall&#8217;allievo Ruggiero De Fazio di Barletta.<br \/>\n<iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/lgAvavaddYk\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<hr \/>\n<p><a href=\"http:\/\/www.gtronic.it\/test\/index.php\/programmazione-plc\/\">back to PLC programming pages<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>How to setup allarms. The alarms generation is handle easily on the HMI interface. Download example TIAV15, CPU 1214C DC\/DC\/DC ag40 -&gt;\u00a0\u00a0Gestione Allarmi Gli allarmi possono essere generati su evento hardware o software, come anche da una richiesta di bordo &hellip; <a href=\"https:\/\/www.gtronic.it\/test\/index.php\/allarmi-impostazione-per-le-cpu-1200-e-1500\/\">Continua a leggere<span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages\/3524"}],"collection":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/comments?post=3524"}],"version-history":[{"count":5,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages\/3524\/revisions"}],"predecessor-version":[{"id":5037,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages\/3524\/revisions\/5037"}],"wp:attachment":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/media?parent=3524"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}