{"id":2186,"date":"2019-04-18T02:28:15","date_gmt":"2019-04-18T00:28:15","guid":{"rendered":"http:\/\/www.gtronic.it\/test\/?page_id=2186"},"modified":"2021-02-13T01:34:34","modified_gmt":"2021-02-13T00:34:34","slug":"how-to-connect-a-mura-decentrate-periferals-in-tia-v15","status":"publish","type":"page","link":"https:\/\/www.gtronic.it\/test\/index.php\/how-to-connect-a-mura-decentrate-periferals-in-tia-v15\/","title":{"rendered":"How to connect a MURR Cube20S decentrate periferals in TIA V16"},"content":{"rendered":"<p>In these example is shown how to install a GSD files for MURR profinet Expansion<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2179\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/periferica-decentrata-MURA.jpg\" alt=\"periferica decentrata MURA\" width=\"1200\" height=\"1600\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/periferica-decentrata-MURA.jpg 1200w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/periferica-decentrata-MURA-225x300.jpg 225w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/periferica-decentrata-MURA-768x1024.jpg 768w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<p>download GSD files-&gt;\u00a0<a href=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/57106_Cube20S_KFG_x_25-2.zip\">57106_Cube20S_KFG_x_25 (2)<\/a><\/p>\n<p>TIA V16 example by prof. Marco Gottardo\u00a0<a href=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murr_tia.zip\">murr_tia<\/a><\/p>\n<p>The system consists of a header module, BN-PN CUBE20S 57106. Two RJ45 Profinet connector is available. One is set, using the dipswitch, to IP 192.168.0.14, the second one is a hub switch. In the second slot there are the power module, useful for share the potential to expansion I\/O. The I\/O in the successive slot are:<\/p>\n<ul>\n<li>DO 2X DC 24V\u00a0 57320<\/li>\n<li>DI 2X DC 24V 57220<\/li>\n<li>DO 8X DC 24V 57380<\/li>\n<li>PD 8X DC 24V\u00a0 57120<\/li>\n<\/ul>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2184\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murra-net.jpg\" alt=\"murra net\" width=\"1600\" height=\"1200\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murra-net.jpg 1600w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murra-net-300x225.jpg 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murra-net-768x576.jpg 768w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murra-net-1024x768.jpg 1024w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2016\/06\/murra-net-400x300.jpg 400w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/><\/p>\n<div class=\"tlid-input input\">\n<div class=\"source-wrap\">\n<div class=\"input-full-height-wrapper tlid-input-full-height-wrapper\">\n<div class=\"source-input\">\n<div class=\"source-footer-wrap source-or-target-footer\">\n<div class=\"character-count tlid-character-count\">\n<div class=\"cc-ctr normal\">\u00a0once the station is inserted into the profinet network it is necessary to install the individual expansion\u00a0 components from the local hardware catalog.\u00a0The I\/O addresses are visible in this section of the software configuration.<\/div>\n<div class=\"cc-ctr normal\">It is essential to change the netbios name of the system to establish communication. You need to add the IP station number by replacing the last digits with the number of the chosen IP. In this example it is 14.<\/div>\n<div class=\"cc-ctr normal\">As shown in the network view, the decentrate periferic is connected to PLC number 3.<\/div>\n<div class=\"cc-ctr normal\">The example explains how to acquire a decentralized input to drive an output on board the compact CPU, and vice versa to drive a decentralized peripheral output by acting on an input on board the CPU.<\/div>\n<div class=\"cc-ctr normal\">Hardware configuration:<\/div>\n<div class=\"cc-ctr normal\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2200\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DI-2x-24-V-DC-57220.png\" alt=\"DI 2x 24 V DC - 57220\" width=\"491\" height=\"534\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DI-2x-24-V-DC-57220.png 491w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DI-2x-24-V-DC-57220-276x300.png 276w\" sizes=\"(max-width: 491px) 100vw, 491px\" \/><\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\">DI 2x 24 V DC &#8211; 57220<\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\"><\/div>\n<\/div>\n<div class=\"cc-ctr normal\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2201\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DO-2x-24-V-DC-0.5-A-57320.png\" alt=\"DO 2x 24 V DC 0.5 A - 57320\" width=\"464\" height=\"525\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DO-2x-24-V-DC-0.5-A-57320.png 464w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DO-2x-24-V-DC-0.5-A-57320-265x300.png 265w\" sizes=\"(max-width: 464px) 100vw, 464px\" \/><\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\">DO 2x 24 V DC 0.5 A &#8211; 57320<\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\"><\/div>\n<\/div>\n<\/div>\n<div class=\"cc-ctr normal\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2202\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DO-8x-24-V-DC-0.5-A-57380.png\" alt=\"DO 8x 24 V DC 0.5 A - 57380\" width=\"460\" height=\"509\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DO-8x-24-V-DC-0.5-A-57380.png 460w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/DO-8x-24-V-DC-0.5-A-57380-271x300.png 271w\" sizes=\"(max-width: 460px) 100vw, 460px\" \/><\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\">DO 8x 24 V DC 0.5 A &#8211; 57380<\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\"><\/div>\n<div class=\"cc-ctr normal\"><\/div>\n<div class=\"cc-ctr normal\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2203\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Terminals-8X24-V-DC-57120.png\" alt=\"Terminals 8X24 V DC - 57120\" width=\"464\" height=\"527\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Terminals-8X24-V-DC-57120.png 464w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Terminals-8X24-V-DC-57120-264x300.png 264w\" sizes=\"(max-width: 464px) 100vw, 464px\" \/><\/div>\n<div class=\"cc-ctr normal\" style=\"text-align: center;\">Terminals 8X24 V DC &#8211; 57120<\/div>\n<div class=\"source-input\">\n<div class=\"source-footer-wrap source-or-target-footer\">\n<div class=\"character-count tlid-character-count\">\n<div class=\"cc-ctr normal\"><\/div>\n<div class=\"cc-ctr normal\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-2193\" src=\"http:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Amazon-Book-PLC-gottardo.png\" alt=\"Amazon Book PLC gottardo\" width=\"1089\" height=\"768\" srcset=\"https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Amazon-Book-PLC-gottardo.png 1089w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Amazon-Book-PLC-gottardo-300x212.png 300w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Amazon-Book-PLC-gottardo-768x542.png 768w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Amazon-Book-PLC-gottardo-1024x722.png 1024w, https:\/\/www.gtronic.it\/test\/wp-content\/uploads\/2019\/04\/Amazon-Book-PLC-gottardo-425x300.png 425w\" sizes=\"(max-width: 1089px) 100vw, 1089px\" \/><\/div>\n<div class=\"cc-ctr normal\">PLC courses in English and Italian available for small groups. Students of all nationalities are accepted. One week full immersion. Location, Padua, Italy, For information contact ad.noctis@gmail.com<\/div>\n<div class=\"cc-ctr normal\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>In these example is shown how to install a GSD files for MURR profinet Expansion download GSD files-&gt;\u00a057106_Cube20S_KFG_x_25 (2) TIA V16 example by prof. Marco Gottardo\u00a0murr_tia The system consists of a header module, BN-PN CUBE20S 57106. Two RJ45 Profinet connector &hellip; <a href=\"https:\/\/www.gtronic.it\/test\/index.php\/how-to-connect-a-mura-decentrate-periferals-in-tia-v15\/\">Continua a leggere<span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages\/2186"}],"collection":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/comments?post=2186"}],"version-history":[{"count":13,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages\/2186\/revisions"}],"predecessor-version":[{"id":3142,"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/pages\/2186\/revisions\/3142"}],"wp:attachment":[{"href":"https:\/\/www.gtronic.it\/test\/index.php\/wp-json\/wp\/v2\/media?parent=2186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}